DIN Rail Mount Load Cell Transmitters: Model PS-1040/45
PS-1040/45 digital/analog transmitters
provide signal conditioning, amplification,
and a corresponding digital or isolated
analog output signal for tank/bin/hopper
weighing systems. Front panel
configuration and calibration streamlines
system installation and operation.
Calibration and configuration parameters
also can be downloaded via PC based
Pro-View Software. In either case, no dip
switch or potentiometer adjustments are
required.
Calibration options accommodate front
panel data entry or dead load weighing
methods.
High level serial communication is
available in RS-232, RS-422, or RS-485
format with Modbus RTU protocol. Up to 32
transmitters can be connected
point-to-point using the RS-485 serial
output.
Vishay BLH offers the PS-121, 24Vdc
Power Supply (data sheet #12155), for
PS-1040/45 operations.
NOTE: Model PS-1040 requires Pro-View
Software for calibration and system
parameter entries.
Product characteristics :
-
DIN rail mount digital/analog transmitter
-
Push button configuration and calibration (PS-1045)
-
10 point load cell linearization
-
Selectable 0-10Vdc or 4-20mA isolated analog output
-
Peak hold functions for dynamic/historic measurement
-
Keypad entry or conventional dead load calibration
-
Serial communication and Modbus RTU protocol
-
Display (PS-1045) and blind (PS-1040) Versions