Industry fair
> Measurement, Analyses and Tools
> Electromagnetic and electric measurement
> Measurement
For measuring and monitoring electrically conductive liquids, pastes and slurries
Versions
DWM 1000 flow switch, 2-wire system
DWM 2000 flowmeter, 4 ... 20 mA current output
Special features
Process temperature: -25 - 150°C / -13 - 302°F
Operating pressure: 25 bar / 360 psig
Rugged design
No moving parts, maintenance-free
Wetted parts of stainless steel or ceramics
Electronic unit replaceable at flowing conditions
For pipelines > DN 50 / > 2''
DWM 2000 FT
The DWM 2000 FT flowmeter measures the flowrates of electrically conductive liquids, pastes and slurries.
Version
DWM 2000 FT flowmeter, 4-20 mA current output
Special features
Designed for Tuchenhagen VARIENT® housings
Wetted parts made of stainless steel (surface roughness ≤ 0.8 µm), ceramics and FDA-approved EPDM, crevice-free
Process temperature up to 135°C or 275°F
Easy, quick and low-cost installation
One device for all nominal pipe sizes
Electromagnetic measuring principle, no moving parts
Electronic unit replaceable under service conditions
Measuring principle
If an electrical conductor is caused to move in a magnetic field, such movement induces a voltage U in the conductor.
In this case, the conductor is the electrically conductive liquid. Magnetic field B is at right angles to the direction of flow. The induced voltage U is directly proportional to the local flow velocity v.
U = k x B x v xD
k Instrument constant
B Strength of magnetic field v Local flow velocity
D Electrode spacing
Voltage U is tapped off from the electrodes, neutral and ground electrode (socket).
DWM 1000 flow switch Voltage U converted into a switching signal with adjustable switching point.
DWM 2000 flowmeter Voltage U converted into a flow-proportional output signal, load-independent current
4-20 mA.