Characteristics
The thermocouple amplifier Type 2205A... amplifies the signal of a temperature sensor into a normalized 0 ... 10 V voltage signal. It was developed for industrial applications and optimized for use with the CoMo Injection Type 2869A… and Kistler sensors.
Applications
The amplifier Type 2205A... is intended for use with Kistler temperature or combined pressure and temperature sensors used in injection molding. It is suitable for mounting in molds at temperatures up to 125 °C. The housing Type 5700A23 is available for use at higher mold temperatures up to 195 °C. It is designed for thermally insulated mounting on a mold.