Liquipoint T FTW31,32
Level limit switch for multiple point detection in conductive liquids.
Product characteristics :
-
Measuring principle : conductive.
Technical data sheet
- Characteristic / Application :
• (1:FTW31) Compact rod probe with multipoint detection, possible up to 5 switch points. Simple rod shortening.
• (2:FTW32) Compact rope probe mit with multi point detection possible up to 5 switch points. Simple rope shortening possible.
- Supply / Communication :
• DC PNP 10,8V ... 45V.
• Relay 20V ... 230V AC.
• Relay 20V ... 55V DC.
- Ambient temperature :
• -40 °C ... 70 °C.
• (-40 °F ... 158 °F).
- Process temperature :
• (1)-40 °C ... 100 °C.
• (-40 °F ... 212 °F).
• (2) -40 °C ... 70 °C.
• (-40 °F ... 158 °F) .
- Process pressure absolute / max. overpressure limit :
• Vacuum ... 10 bar.
• (Vacuum ... 145 psi).
- Min. density of medium :
• min. 10 uS.
- Main wetted parts :
• (1)316L, PP, PPS.
• (2)316L, FEP, PPS.
- Max. tensile strength :
• (1)1000 N.
• (2)500 N.
- Process connection :
• G 1 1/2.
• NPT1 1/2 .