Liquiphant T FTL20, FTL20H
Level limit switch for liquids.
Product characteristics :
-
Measuring principle : Vibration liquids.
Technical data sheet
- Characteristic / Application :
• (1) Most compact device.
• Media independent.
• Focus factory automation..
• (2)Most compact.
• Hygiene housing and process connections CIP / SIP.
• Switch point 38mm.
• EHEDG approvals.
- Supply / Communication :
• 19 ... 253V AC.
• 10 ... 35V DC-PNP.
• ASI-Bus.
- Ambient temperature :
• -40 °C ... 70 °C (-40 °F ... 158 °F).
• ASi -25 °C ... 70 °C (ASi -13 °F ... 158 °F).
- Process temperature :
• -40 °C ... 150 °C (-40 °F ... 302 °F).
- Process pressure absolute / max. overpressure limit :
• Vacuum ... 40 bar (Vacuum ... 580 psi).
- Min. density of medium :
• 0,7g/cm³.
• (0,4g/cm³ optional).
- Main wetted parts :
• 316L.
- Process connection :
• G1/2A, G3/4A, G1A, NPT1/2, NPT3/4, R1/2, R3/4.
- Process connection hygienic :
• (1)Flush mount by use of weld in adapter.
• (2)Tri-Clamp ISO2852.
• Dairy coupling.
• Flush mount solutions.