Industry fair   > Measurement, Analyses and Tools   > Sensors   > Pressure sensors  

Pressure Transmitter for OEM Applications

Fields:  Type  CTX_CTL 
 
Application:  OEM markets: Machine equipment, water treatment, water distribution, energy (diesel engines, cogeneration plants), automatic sequence control etc. 
 
Pressure ranges:  CTX: from -1...1,5 to 0...200 bar
CTL: from -1...1,5 to 0....40 bar  
 
Type of pressure:  Gauge pressure 
 
Static error band typ.:  Typ: ±0,4% FS / Max.: ±0,5% FS 
 
Operation temp.:  -40...100°C 
 
Output signal:  4...20 mA
0...10 VDC, 1...5 VDC, 0,5...4,5 VDC 
 
Pressure connection:  G 1/4, G 1/4 DIN 3852, G 1/2, 1/4 NPT, 1/2 NPT
stainless steel (CTX) or brass (CTL)



Transmetteur de pression pour aplications OEM Druckmessumformer für OEM-Anwendungen

More offers for BAUMER BOURDON HAENNI

Open your online booth in less than 1 hour - click here